ICM Controls ICM6701 Water Heater Direct Spark Ignition Control
- $93.41
ICM Controls ICM6701 Water Heater Direct Spark Ignition Control
Description:
With a heat call from the thermostat; the ICM6701 will begin a 15 second on delay, after the delay the gas valve and spark ignitor are energized and the control will check for the presence of flame.
Once flame is detected the spark ignitor is turned off while the gas valve remains energized.
Once the thermostat’s demand for heat ends, the gas valve is immediately de-energized.
If flame is not sensed after 7 seconds, another 15 second on delay will begin followed by a second ignition sequence.
If flame has not been established after three trials for ignition, the control will de-energize the gas valve immediately and the control will go into a hard lockout.
To reset the hard lockout; power must be removed from the control for at least 3 seconds.
General Features:
Water Heater Direct Spark Ignition Control
Direct Spark Ignition (DSI) control board
Monitors timing, Trial for ignition, flame sensing and lockout
Microprocessor-based precision
Designed for 100% gas shutoff in the case of ignition failure
Specifications:
Replaces:
Dimensions:
Product Height (in.): 1.75”
Product Width (in.): 2.5”
Product Depth (in.): 4.9”
Thumb | File information |
Installation Manual.pdf File Size 200.76KB Downloaded: 81 | |
Specification Sheet.pdf File Size 987.53KB Downloaded: 54 |
Reviews
There are no reviews for this product.