Description:


  • Suburban Replacement. This ignition control circuit board works on all Suburban 12V furnaces and Suburban water heater model 520820.

  • When the thermostat calls for heat, the ICM6700 will verify the sail switch is open before energizing the inducer blower. 

  • Once the inducer blower is energized, the ICM6700 will verify the sail switch has closed and begin a 15 second pre-purge cycle. 

  • Following the inducer blower pre- purge cycle, the gas valve and spark ignitor are energized and the ICM6700 will verify the presence of flame.

  • If flame has not been sensed after 7 seconds; the control will attempt 2 more trials for ignition, if flame is not sensed after 3 trials for ignition, the ICM6700 will enter a 1-hour lockout. 

  • If flame is detected, the spark ignitor is turned off and the gas valve remains energized. Once the thermostat is satisfied, the gas valve is de-energized immediately and a 90 second post-purge cycle of the inducer blower is enforced. 

  • After the 90 second post purge cycle, the inducer blower is turned off. 


  • Note: Lockout is cleared by recycling the input voltage.


General Features:


  • Direct Spark Ignition (DSI) control board

  • Monitors timing, Trial for ignition, flame sensing and lockout

  • Designed for 100% gas shutoff in the case of ignition failure

  • Microprocessor-based precision

  • Designed for 100% gas shutoff in the case of ignition failure


Specifications:


Input

Voltage

12 VDC

Current Draw

100mA max.

Output

Gas Valve: N.O.

0.5A @ 12 VDC

Inducer Blower

3.7A @ 12 VDC

Time Delay

Trial for Ignition

7 seconds

ON Delay

15 seconds

OFF Delay

90 seconds


Replaces: 


Fenwal

06-236879-002

Suburban

521099

35-533900-113


Thumb File information
pdf-50x50.png Installation manual.pdf 250.98KB 48
pdf-50x50.png Specification Sheet.pdf 907.42KB 38

Reviews

There are no reviews for this product.

  • 0%
  • 0%
  • 0%
  • 0%
  • 0%

Reviews Over ICM Controls ICM6700 12 VDC Direct Spark Ignition Control Board

Total Reviews (0)
click here write review to add review for this product.