Categories
HVAC Equipment & Parts
- Air Handlers
- Air-To-Water Heat Pumps
- Condensate Overflow Shut-off Switches
- Condensate Removal & Management
- Condenser Pads
- Condensers (Outdoor Units)
- E-Z Traps
- Electric Heat Kits
- Furnaces
- Gas Furnace and A/C Systems
- Gas-Fired Unit Heaters
- Geothermal Units
- Goodman Replacement Parts
- Heat Pumps
- Indoor Units
- Install & Duct Tape
- Installation Accessories
- Linesets
- Miscellaneous Supplies
- Mounting Brackets
- Mr. Cool Universal Series
- Packaged Units
- Portable AC and Heat Units
- Refrigerant Coils
- Secondary Drain Pans
- Service Parts
- Sheet Metal Duct & Fittings
- Surge Protection
- Thermostats and Thermostat Wire
- Through The Wall Units
- Window Units
- More categories
Mini-Splits & Accessories
- Concealed Indoor Units
- Ducted Air Handler
- Ducted Mini-Split Air Handler
- Ductless Accessories
- Electric Heater Module
- Indoor Ceiling Cassettes
- Indoor Wall Mounted
- Intelli-HEAT Coil
- Mini Split Wire & Cable
- Mini-Split Risers
- Mitsubishi Mini-Splits
- Mr. Cool Ductless Mini-Splits
- Outdoor Units, Multi-Zone
- Outdoor Units, Single-Zone
- ProFit Quick Connect Fittings
- More categories
SANCO2 ECO-285GLNST 285 Gallon High Efficient Commercial Storage Tank
SANCO2 ECO-285GLNST 285 Gallon High Efficient Commercial Storage Tank
General specs
- Product codeECO-285GLNST
- ManufacturerEco2 Systems
- SKUECO-285GLNST
Dimensions
- Dimensions0.00in x 36.00in x 80.00in
- Weight550.00lb
SANCO2 285 Gallon High Efficient Commercial Storage Tank
Description:
ASME certified 285 (Actual) Gallon Vertical Glass lined Tank, coated R16 Insulation Top Coat for High R value Insulation.
125 Psig ASME approved Pressure Relief Valve, Thermistor, Thermal Well, Diverter Dip included.
Construction:
The tank shall be manufactured from carbon steel with a baked on Ultonium porcelain enamel lining
Tank outer shell shall be covered with a spray on foam insulation with an acrylic top coat to allow both interior and exterior installation
Tank shall have ECO2 stenciled on the Insulation top coat
Insulation:
A minimum of 2 1/4" of R7.5 insulation shall be sprayed on to the tank to reduce heat loss and comply with California
Title 24 requirements
Connections:
Connections to the Hot and Cold building supplies shall be 3" NPT Female type
Connection to Cold supply from the tank to the Heat Pump shall be 1 1/2" NPT male type
Connection to Hot return from the Heat Pump to the tank shall be 1 1/2" NPT female type
Controls:
The tank shall be supplied with a Temperature sensor well for field installation so that Tank Temperature sensors are able to be inserted
Each Heat Pump connected to the Storage Tank shall require a 91101-45190 temperature sensor to be field installed in the Sensor well and wired directly to the Heat Pump
If the ECO-MSCTRL-01 Multi Unit Controller shall be used, it shall be supplied with Temperature sensors for field installation
All sensors shall be field installed
Pressure and Temperature Relief:
Tank shall be supplied with a field installed, ASME approved Pressure relief valve
Valve Setting shall be at 125 Psig
Relief Valve shall be piped to a suitable location in case of discharge
Specifications:
Type | Storage Tank |
Tank Volume Actual/Nominal | 285 / 318 Gallons |
Pressure Relief Valve (Psig & °F) | 125 Psig |
Temperature Sensor | Thermistor |
Anodes | 3 x Magnesium |
Cold Water Inlet | 3" NPT |
Hot Water Outlet | 3" NPT |
Cold Water to Heat Pump | 1 1/2" NPT |
Hot Water Return from HP | 1 1/2" NPT |
Max Pipe Length inc | 66ft |
Max Vertical Separation of | 23ft |
Dimensions:
Product Height (in.): 80”
Product Width (in.): 36”
Unit Weight: 550 lbs.
Warranty: