Categories
HVAC Equipment & Parts
- Air Handlers
- Air-To-Water Heat Pumps
- Condensate Overflow Shut-off Switches
- Condensate Removal & Management
- Condenser Pads
- Condensers (Outdoor Units)
- E-Z Traps
- Electric Heat Kits
- Furnaces
- Gas Furnace and A/C Systems
- Gas-Fired Unit Heaters
- Geothermal Units
- Goodman Replacement Parts
- Heat Pumps
- Indoor Units
- Install & Duct Tape
- Installation Accessories
- Linesets
- Miscellaneous Supplies
- Mounting Brackets
- Mr. Cool Universal Series
- Packaged Units
- Portable AC and Heat Units
- Refrigerant Coils
- Secondary Drain Pans
- Service Parts
- Sheet Metal Duct & Fittings
- Surge Protection
- Thermostats and Thermostat Wire
- Through The Wall Units
- Window Units
- More categories
Mini-Splits & Accessories
- Concealed Indoor Units
- Ducted Air Handler
- Ducted Mini-Split Air Handler
- Ductless Accessories
- Electric Heater Module
- Indoor Ceiling Cassettes
- Indoor Wall Mounted
- Intelli-HEAT Coil
- Mini Split Wire & Cable
- Mini-Split Risers
- Mr. Cool Ductless Mini-Splits
- Outdoor Units, Multi-Zone
- Outdoor Units, Single-Zone
- ProFit Quick Connect Fittings
- More categories
Robertshaw 780-001 Non-Lockout Universal Ignition Control
Robertshaw 780-001 Non-Lockout Universal Ignition Control
General specs
- Product code780-001
- ManufacturerRobertshaw
- SKU780-001
Dimensions
- Dimensions7.60in x 5.10in x 4.40in
- Weight1.00lb
Robertshaw 780-001 Non-Lockout Universal Ignition Control
Description:
The Robertshaw® 780 Series Pilot Controls Uni-Kits® feature a flame sense circuit that will work equally well on a one rod (local sense) or a two rod (remote sense) application.
The automatic recycle features assure that, in the event of flame failure, main gas is disabled and the spark repetition sequence is restarted until pilot gas is ignited.
Only after pilot ignition has been re-established can main gas be returned to the burner.
The Robertshaw lockout version kits include the capability to shut off all gas to the furnace, should pilot ignition fail to occur after a predetermined time period.
The 780-002 provides three tries for ignition.
Each ignition period is 90 seconds followed by a six minute time delay between ignition attempts.
If the pilot flame is not sensed after three tries, the unit goes into lockout and must be reset at the thermostat.
General Features:
Replaces one rod and/or two rod systems
Reduces truck stock inventory, saving space and money
Includes vent damper adapter assembly
Easy-to-install with complete in-depth installation instructions
Pilot and main valves draw 1 Amp at 0.5 power factor
Combined load at 1.5 Amps at 0.4 power factor
95% relative humidity non condensing at 104°F
Specifications:
Series Application | Gas Ignition Control - Non Lockout |
Spark Rate | 3 to 4 per second |
Maximum Total Current Load | 1.5 Amps |
Flame Failure Re-Ignition Time | 0.8 seconds |
Thermostat Anticipator Setting | 0.7 Amps |
Temperature Range | -40°F to 175°F |
Flame Sensor Current | 0.7 mA DC @ 25°C |
Transformer | 24V AC, 20VA |
Control Voltage | 24V AC 50/60 Hz |
Dimensions:
Shipping Height (in.): 4.4”
Shipping Width (in.): 5.1”
Shipping Depth (in.): 7.6”
Shipping Weight: 1 lbs.