Live chat
Support1-215-316-5893(Guest ID: )

Rheem RHMV2421HEACJA 2 Ton 2-Stage Multi-Position Air Handler, R-410A

$1,524.79
Category:Air Handlers
Manufacturer:Rheem
Product code:RHMV2421HEACJA
Available

Delivery Information

Shipping available
Pick your shipping method at checkout.
Rheem RHMV2421HEACJA 2 Ton 2-Stage Multi-Position Air Handler, R-410A
$1,524.79

General specs

  • Product codeRHMV2421HEACJA
  • ManufacturerRheem
  • SKU

Dimensions

  • Dimensions (L x W x H)21.69in x 21.00in x 55.50in
  • Weight130.00 lb

Technical Specifications

  • Nominal Tons 2 Ton
  • Refrigerant R-410A
  • Voltage 208/240
  • RHMV Series Specification Sheet

Rheem RHMV2421HEACJA 2 Ton 2-Stage Multi-Position Air Handler, R-410A

Features

  • The RHMV is EcoNet Enabled: This allows the RHMV to directly communicate with the EcoNet Smart Home System.
  • The RHMV features an Electronic Expansion Valve (EEV)
  • Features a constant CFM variable speed motor (ECM) which provides enhanced SEER performance. The RHMV is rated with RA17, RA20 air conditioners and RP17, RP20 heat pumps
  • Evaporator is constructed of aluminum fins bonded to internally grooved aluminum tubing.
  • Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.
  • Sturdy cabinet construction with 1.0 inch [25.4 mm] of foil faced insulation for excellent sound and insulating characteristics.
  • Field-installed auxiliary electric heater kits provide exact heat for indoor comfort. Kits include circuit breakers which meet U.L. and cUL requirements for service disconnect.
  • Enhanced airflow up to .7" external static pressure.
  • Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing.
  • Coils have copper sweat refrigerant connections
  • Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils.
  • Supply duct flanges provided as standard on air handler cabinet.
  • Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet.
  • Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2 inches [51 mm] for 11/2 inch [38 mm] conduit.
  • Front refrigerant and drain connections.

Specifications

  • Tonnage 2
  • Stages of Operation Modulating
  • Refrigerant Type R410A
  • Coil Efficiency High
  • Metering Device EEV
  • Communication EcoNet Enabled
  • Voltage Data (Volts-Phase-Hz) 208/240/1/60
  • Configuration 4-way Convertible
  • Supply Opening (Inches) 19.5W X 10.26D
  • Return Opening (Inches) 19.3W X 19.75D
  • Refrigerant Connections Sweat (In.) 3/8 Liquid 7/8 Vapor
  • Motor Type/HP 1/2 VS-CT (ECM)
  • Motor RPM Variable
  • Motor # of Speeds Variable
  • Blower Wheel 10x10
  • CFM Rating 800-1600 CFM
  • Application Air Handler Modulating

Top