Live chat
Support1-215-316-5893(Guest ID: )

Rheem RH2V3621MTANJA 3 Ton Two Stage Air Handler, R-410A

$2,014.90
Category:Air Handlers
Manufacturer:Rheem
Product code:RH2V3621MTANJA
Available

Delivery Information

Distribution Facility, Pennsylvania
Available for pickup:7
Shipping available
Pick your shipping method at checkout.
Rheem RH2V3621MTANJA 3 Ton Two Stage Air Handler, R-410A
$2,014.90

General specs

  • Product codeRH2V3621MTANJA
  • ManufacturerRheem
  • SKU

Dimensions

  • Dimensions (L x W x H)21.60in x 21.00in x 50.50in
  • Weight135.00 lb

Technical Specifications

  • Motor Type Variable Speed
  • Nominal Tons 3 Ton
  • Refrigerant R-410A
  • RH2V Series Specification Sheet

Rheem RH2V3621MTANJA 3 Ton Two Stage Air Handler, R-410A, Variable Speed

Features

  • Quiet, efficient ECM motor technology providing nominal airflow up to 1.0 inch [25 kPa] of external static pressure.
  • Interface board with dip switches conveniently located in the blower compartment allows for precise, field selectable airflow to meet the requirements of particular applications.
  • 1.0" foil faced insulation mechanically retained in the blower compartment.
  • Four leg rubber insulated motor mount
  • Field-installed auxiliary heater kit includes circuit breakers that meet UL and cUL requirements as a service disconnect switch.
  • Blower housing with integrated controls, motor and blower. Slide out design for service and maintenance convenience
  • Field convertible for vertical upflow, vertical downflow, horizontal left hand or right hand air supply.
  • Combustible floor base accessory available when required for downflow installations on combustible floors.
  • Indoor coil design provides low air side pressure drop, high performance and extremely compact size. All coils come with PVC condensate elbow standard.
  • Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing.
  • Coils have copper sweat refrigerant connections.
  • Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils.
  • Supply duct flanges provided as standard on air handler cabinet.
  • The connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet.
  • Front refrigerant and drain connections.

Specifications

  • Tonnage 3
  • Stages of Operation 2-Stage
  • Refrigerant Type R410A
  • Coil Efficiency Medium
  • Metering Device TEV
  • Communication Non-Communicating
  • Voltage Data (Volts-Phase-Hz) 208/240/1/60
  • Configuration 4-way Convertible
  • Supply Opening (Inches) 19.5W X 10.26D
  • Return Opening (Inches) 19.3W X 19.75D
  • Refrigerant Connections Sweat (In.) 3/8 Liquid 7/8 Vapor
  • Motor Type/HP 3/4 VS-CT (ECM)
  • Motor RPM Variable
  • Motor # of Speeds Variable
  • Blower Wheel 10x10
  • CFM Rating 600-1200 CFM
  • Application Air Handler 2-Stage

Top