General specs

  • Product codeX-300
  • ManufacturerReznor
  • SKUX-300

Dimensions

  • Dimensions28.00in x 41.25in x 35.25in
  • Weight286.00lb

Technical Specifications

  • Blower Motor Type Multi-Speed
  • Efficiency 80 %
  • Frequency 60 Hz
  • Fuel Type Natural Gas
  • Gas Connection Size 3/4"
  • Heating Capacity 240000 Btu
  • High-Fire Input Capacity 300,000 Btu
  • Max. Airflow 4420 CFM
  • Min. Airflow 2455 CFM
  • Mounting Suspended
  • Phase 1
  • Product Type Unit Heater
  • Stages Single Stage
  • Vent Type Chimney Vent
  • Voltage 120 V
  • Installation Manual
  • Submittal Sheet
  • Parts Manual
  • Catalog

Reznor X-300 300,000 BTU Gas Fired Duct Furnace - Gravity Vented - NG - 409 Stainless Steel Heat Exchanger

Description:

  • Reznor X Series Duct Furnaces are designed to provide 80% thermal efficiency for indoor application with gravity venting.
  • They are certified for use with natural or propane gas, as specified, in sizes from 75,000 through 400,000 BTUH input.
  • These models are used as heating components in heating, heating/cooling, or makeup air systems and require a separate blower system for air delivery.
  • The furnace has a Reznor Thermocore® aluminized steel heat exchanger with venturi-design tubes.
  • The die-formed burners are of aluminized steel and include flared ports with a stainless steel insert.
  • The Model X furnace is approved for a temperature rise of 50°F to 90°F and includes “finger-baffles” for proper air distribution at these lower air volumes.
  • Removing the finger-baffles increases the air flow.
  • These field converted units are approved for a temperature rise of 20°F to 75°F.
  • Standard features include a spark ignition pilot and a single-stage, 24-volt gas valve.
  • Model X units are wired for field connection to a remote 24-volt thermostat for automatic operation.
  • Each unit is provided with all required limit and safety controls, including a blocked vent shut-off system.

General Features:

  • Orifices for natural gas
  • Aluminized steel heat exchanger
  • Aluminized steel burners with stainless steel insert
  • 120-volt supply voltage
  • 24 volt control voltage transformer
  • High limit safety cutout
  • Single-stage combination gas valve (see note 1)
  • Side access for burners and controls (left side facing air stream)
  • Horizontal or vertical flue discharge
  • Spark-ignited pilot
  • Fan control
  • Terminal blocks for connecting field wiring
  • Blocked vent shut-off system