Categories
HVAC Equipment & Parts
- Air Handlers
- Air-To-Water Heat Pumps
- Condensate Overflow Shut-off Switches
- Condensate Removal & Management
- Condenser Pads
- Condensers (Outdoor Units)
- E-Z Traps
- Electric Heat Kits
- Furnaces
- Gas Furnace and A/C Systems
- Gas-Fired Unit Heaters
- Geothermal Units
- Goodman Replacement Parts
- Heat Pumps
- Indoor Units
- Install & Duct Tape
- Installation Accessories
- Linesets
- Miscellaneous Supplies
- Mounting Brackets
- Mr. Cool Universal Series
- Packaged Units
- Portable AC and Heat Units
- Refrigerant Coils
- Secondary Drain Pans
- Service Parts
- Sheet Metal Duct & Fittings
- Surge Protection
- Thermostats and Thermostat Wire
- Through The Wall Units
- Window Units
- More categories
Mini-Splits & Accessories
- Concealed Indoor Units
- Ducted Air Handler
- Ducted Mini-Split Air Handler
- Ductless Accessories
- Electric Heater Module
- Indoor Ceiling Cassettes
- Indoor Wall Mounted
- Intelli-HEAT Coil
- Mini Split Wire & Cable
- Mini-Split Risers
- Mitsubishi Mini-Splits
- Mr. Cool Ductless Mini-Splits
- Outdoor Units, Multi-Zone
- Outdoor Units, Single-Zone
- ProFit Quick Connect Fittings
- More categories
ICM Controls ICM6501 Fan Blower, ClimaTek Air Handling Replacement Control
ICM Controls ICM6501 Fan Blower, ClimaTek Air Handling Replacement Control
General specs
- Product codeICM6501
- ManufacturerICM Controls
- SKUICM6501
Dimensions
- Dimensions2.50in x 3.00in x 10.00in
- Weight2.00lb
ICM Controls ICM6501 Fan Blower, ClimaTek Air Handling Replacement Control
Description:
The ICM6501 air handler control board operates with hot water heating systems.
When the thermostat calls for Heat, the control will energize the Water Pump, Valve and Boiler.
The blower will energize at the selected speed after 90 seconds to allow the coil to preheat.
General Features:
Controls the water pump, valve, fan and boiler in a hot water heating system
Jumper selectable high and low speed fan speed selection for 2 speed blower operations
Integral fan delays for both heating and standard fan operation
Monitors safety switches including the pressure switch and freeze protection switch
Test mode feature for system diagnostic purposes
LED status Light to aid in diagnosing power issues
Specifications:
Input Voltage | 24 VAC, 120/240 VAC, 50/60 Hz |
Valve Output | 24 VAC, 50/60 Hz, 5A |
Blower Fan | 120/240 VAC, 50/60 Hz, 9.8 FLA |
Water Pump | 120/240 VAC, 50/60 Hz, 1.5 FLA |
Boiler | 24 VAC, 50/60 Hz, 5A |
Surrounding Air Temperature Rating | -40ºF to 167ºF (-40ºC to 75ºC) |
Timing | |
Fan on delay | 0 seconds |
Fan off delay | 45 seconds |
Heat fan on delay | 90 seconds |
Heat fan off delay | 20 seconds |
Replaces:
ClimaTek | CB201 |
First Company | CB201 |
Dimensions:
Product Height (in.): 10”
Product Width (in.): 3”
Product Depth (in.): 2.5”
Unit Weight: 2 lbs.