- More categories
ICM Controls ICM402C Three-phase Line Voltage Monitor
ICM Controls ICM402C Three-phase Line Voltage Monitor
General specs
- Product codeICM402C
- ManufacturerICM Controls
- SKUICM402C
Dimensions
- Dimensions3.25in x 3.00in x 1.25in
- Weight0.45lb
ICM Controls ICM402C Three-phase Line Voltage Monitor
Description:
If all 3 phases are relatively equal and in proper sequence, the normally open contacts (Y/Y-OUT) will close when 115/230 volts is applied between C and 115/230 VAC terminals.
If the phases are out of sequence, or if one is missing, the contacts will never close.
If a phase is lost while the ICM402 is energized, the contacts will open immediately and will remain open until the error is corrected.
An illuminated green LED indicates that the output is energized, and an illuminated red LED indicates that there is a fault and the output is de-energized.
General Features:
Low cost 3 phase protection for single side
Monitors for phase reversal, phase loss, unbalance % as a function of input voltage
Bright LED indicators for ON and FAULT
Universal 3 phase input: 190-600 VAC
Highly reliable passive electronics
Easy to install, no adjustments
Less than 1 second phase loss response
Automatic reset from a fault condition
Compact packaging: fits almost anywhere
Epoxy coated for added protection
Works great with the ICM450 for load side monitoring of part winding start motors and multiple compressor systems
For open board model, order ICM404
Specifications:
Voltage | 190-600 VAC |
Frequency | 50/60 Hz |
Control | 115 or 208/240 VAC |
Output Relay | SPST |
Output N.O. | 30 amps |
Replaces:
Supco | TPMP2 |
Mars | 32536 |
ICM | |
ICM402-BA7106 | ICM402C-LF |
AH7102 |
Dimensions:
Product Height (in.): 1.25”
Product Width (in.): 3”
Product Length (in.): 3.25”
Unit Weight: 0.45 lbs.