Categories
HVAC Equipment & Parts
- Air Handlers
- Air-To-Water Heat Pumps
- Condensate Overflow Shut-off Switches
- Condensate Removal & Management
- Condenser Pads
- Condensers (Outdoor Units)
- E-Z Traps
- Electric Heat Kits
- Furnaces
- Gas Furnace and A/C Systems
- Gas-Fired Unit Heaters
- Geothermal Units
- Goodman Replacement Parts
- Heat Pumps
- Indoor Units
- Install & Duct Tape
- Installation Accessories
- Linesets
- Miscellaneous Supplies
- Mounting Brackets
- Mr. Cool Universal Series
- Packaged Units
- Portable AC and Heat Units
- Refrigerant Coils
- Secondary Drain Pans
- Sensors
- Service Parts
- Sheet Metal Duct & Fittings
- Surge Protection
- Thermostats and Thermostat Wire
- Through The Wall Units
- Window Units
- More categories
ICM Controls ICM292A DSI Gas Ignition Replacement Control Board For Rheem 62-24140-04

ICM Controls ICM292A DSI Gas Ignition Replacement Control Board For Rheem 62-24140-04
General specs
- Product codeICM292A
- ManufacturerICM Controls
- SKUICM292A
Dimensions
- Dimensions5.75in x 6.60in x 2.25in
- Weight0.60 lb
ICM Controls ICM292A DSI Gas Ignition Replacement Control Board For Rheem 62-24140-04
Description:
The ICM292A is a low-cost DSI gas ignition control that replaces the following Rheem model: 62-24140-04.
The ICM292A has incorporated LED diagnostics to assist in troubleshooting.
Fault code information can be found in the application guide.
Please refer application guide with the furnace installation manual for future reference.
General Features:
Low cost form, fit and functional replacement for Rheem: 62-24140-04
Direct Spark Ignition (DSI) control
Microprocessor-based
Controls induced draft and indoor blower motor; humidifier output, spark ignitor and gas valve
Monitors timing, trial for ignition, flame sensing and lockout
100% lockout safety feature
Compatible with LP or natural gas
Status LEDs for fault codes to aid in troubleshooting
Specifications:
Control voltage | 24 VAC (18-30 VAC), 60 Hz |
Line Voltage | 115 VAC, 60 Hz |
Power cons | 0.3A plus gas valve current at 24 VAC |
Operating temperature | 5% – 95% (non-condensing) at +55°C |
Timing | |
Pre-purge | 30 seconds |
Trial for ignition | 7 seconds |
Retries | Two groups of two, 30 seconds delay within the group and 3 minutes delay between groups |
Lockout | 1 hour |
Post-purge | 90, 120, 160 and 180 seconds |
Inputs | |
Power | 24 VAC and COM |
Thermostat interface | R, W, Y and G |
System switches | Vent pressure and limit switches (main and over-temperature switches in series) |
Flame Sensing | |
Heat blower OFF delay | SW1 toggle switch |
Outputs | |
Gas Valve | 3A Pilot Duty @ 120 VAC |
Draft Inducer Motor | 3A max., 1/6 HP @ 125 VAC |
Cool Blower | 16A max., 1/2 HP @ 277 VAC |
Heat Blower | 14A max., 1/2 HP @ 277 VAC |
Circulating Fan | 12A max., 1 HP @ 125 VAC |
Heat/Cool Fan | 10 A max., 1/2 HP @ 277 VAC |
Electronic Air Cleaner | 10 A max., 1HP @ 125 VAC |
Humidifier | 11 A max., 1/6 HP @ 125 VAC |
LED Indicators | |
Power, green LED | PWR |
Status, green LED | OK |
Flame status, yellow LED | FLAME |
Replaces:
Rheem | 62-24140-04 |
Dimensions:
Product Height (in.): 2.25”
Product Width (in.): 6.60”
Product Depth (in.): 5.75”
Unit Weight: 0.6 lbs.