ICM Controls ICM2914 Trane Replacement Furnace Board
![](https://skipthewarehouse.com/image/cache/products/icm-controls-icm2914-trane-replacement-furnace-board-764x764.webp)
ICM Controls ICM2914 Trane Replacement Furnace Board
General specs
- Product codeICM2914
- ManufacturerICM Controls
- SKUICM2914
Dimensions
- Dimensions5.50in x 4.75in x 1.50in
- Weight0.38 lb
ICM Controls ICM2914 Trane Replacement Furnace Board
Description:
The ICM2914 is a form, fit, and functional replacement for Trane Spark Ignition Control: D674712P01 shown in the cross-reference section of the guide.
The control boards are designed as automated gas ignition controls that monitor the ignition sequence including the inducer, pressure switch, spark ignition, gas valve, flame sense, and circulating blower while maintaining full safety circuit monitoring including the high limit switch, roll out switch and auxiliary limit switch circuits.
General Features:
Controls blower motors, gas valve, & spark ignitor in sequence
Protects against short cycling
Selectable Heat/Cool blower off-delay time
Flash codes from the onboard LED indicate specific problems for easier troubleshooting
Repeated ignition failures or flame losses will disable heat operation for safety
Specifications:
Line voltage | 460 VAC |
Line frequency | 50/60 Hz |
Control voltage | 18-30 VAC |
Circulator blower | 4FLA @ 277 VAC |
Hi-efficiency blower | 10 mA @ 24 VAC |
Inducer blower | 10 mA @ 24 VAC |
Combined gas valve load | 1.5 A @ 24 VAC |
Minimum flame signal threshold | 0.75 uA |
Replaces:
Trane Spark Ignition Control | D674712P01 |
Dimensions:
Product Height (in.): 1.5”
Product Width (in.): 4.75”
Product Depth (in.): 5.5”
Unit Weight: 0.38 lbs.