ICM Controls ICM281 Furnace Control Replacement For Carrier
ICM Controls ICM281 Furnace Control Replacement For Carrier
General specs
- Product codeICM281
- ManufacturerICM Controls
- SKUICM281
Dimensions
- Dimensions7.63in x 8.50in x 0.75in
- Weight0.60 lb
ICM Controls ICM281 Furnace Control Replacement For Carrier
Description:
The ICM281 is a low cost replacement for the Carrier CES0110020, CES0110048 and CES0110057-xx series, furnace control boards which is used to control gas valve, ignitor, blower motor, inducer, humidifier and air cleaner.
The ICM281 has incorporated LED diagnostics to assist in troubleshooting.
It is recommended that a sight glass (not included) be installed in a convenient location on the furnace to take advantage of this feature.
If a sight glass is not installed, the self-test feature of the board can still be used for routine troubleshooting.
A fault code label is included in this package and must be installed on the furnace.
General Features:
Controls gas valve, ignitor, blower motor, inducer, humidifier and air cleaner
Microprocessor-based for precise timing
Functions with all 24 VAC thermostats
Designed for 100% gas shutoff in case of ignition failure
Twinning compatible with another ICM281 board
Reverse polarity protection
Secondary brownout voltage protection
Diagnostic fault codes (blinking LED) for simple troubleshooting
Specifications:
Product Type | Furnace Control |
Voltage | Line (98/132 VAC) @ 60 Hz |
Ignitor | 5A @ 120 VAC |
Cool Blower | 30A, 2HP, 240 VAC |
Heat | 5A, 1/2 HP, 240 VAC |
Inducer Motor | 4A, FLA-8.0 LRA @ 120 VAC |
Gas Valve | 1.5A @ 30 VAC |
Operating Temp Range | -40° to 176°F |
Replaces:
Carrier | |
CES0110020 | CES0110048 |
CES0110057-00 | CES0110057-01 |
CES0110057-02 | HH84AA016 |
Dimensions:
Product Height (in.): 0.75”
Product Width (in.): 8.5”
Product Depth (in.): 7.625”
Unit Weight: 0.6 lbs.