Categories
HVAC Equipment & Parts
- Air Handlers
- Air-To-Water Heat Pumps
- Condensate Overflow Shut-off Switches
- Condensate Removal & Management
- Condenser Pads
- Condensers (Outdoor Units)
- E-Z Traps
- Electric Heat Kits
- Furnaces
- Gas Furnace and A/C Systems
- Gas-Fired Unit Heaters
- Geothermal Units
- Goodman Replacement Parts
- Heat Pumps
- Indoor Units
- Install & Duct Tape
- Installation Accessories
- Linesets
- Miscellaneous Supplies
- Mounting Brackets
- Mr. Cool Universal Series
- Packaged Units
- Portable AC and Heat Units
- Refrigerant Coils
- Secondary Drain Pans
- Service Parts
- Sheet Metal Duct & Fittings
- Surge Protection
- Thermostats and Thermostat Wire
- Through The Wall Units
- Window Units
- More categories
Mini-Splits & Accessories
- Concealed Indoor Units
- Ducted Air Handler
- Ducted Mini-Split Air Handler
- Ductless Accessories
- Electric Heater Module
- Indoor Ceiling Cassettes
- Indoor Wall Mounted
- Intelli-HEAT Coil
- Mini Split Wire & Cable
- Mini-Split Risers
- Mitsubishi Mini-Splits
- Mr. Cool Ductless Mini-Splits
- Outdoor Units, Multi-Zone
- Outdoor Units, Single-Zone
- ProFit Quick Connect Fittings
- More categories
ICM Controls ICM206B Delay On Break Timer
ICM Controls ICM206B Delay On Break Timer
General specs
- Product codeICM206B
- ManufacturerICM Controls
- SKUICM206B
Dimensions
- Dimensions2.00in x 2.00in x 1.25in
- Weight0.15lb
ICM Controls ICM206B Delay On Break Timer
Description:
Delay on Break Timers ("anti-short cycle", "ON delay on break") helps to protect air conditioning, refrigeration and heat pump equipment from damage which may be caused by the rapid short cycling of compressors.
Upon application power, the load is energized.
When the thermostat or other switch opens or there is a loss of power, the load is de-energized and the delay period begins.
The compressor will not start again during the delay period.
Restart occurs after the delay period has elapsed.
General Features:
Compressor lockout/anti-short cycle timer
Brownout protection
UL 873 recognition as compressor controller
Helps prevent scroll compressor reversal
Fast response time: 16ms
Prevents low voltage starts
Eliminates relay chatter due to thermostat bounce or tampering
Works with anticipator-type thermostats
18-30 VAC
Specifications:
Time Delay | 3-10 Min Adjustable |
Product Type | Delay on Break |
Voltage | 18/30 VAC |
Amperage | 1.5 |
Amp Inrush | 15 |
Holding Current | 40 mA (minimum) |
Frequency | 50-60 Hz |
Size | 2" x 2" |
Replaces:
A-1 | EAC-426-ADJ |
Supco | TD74 |
Dimensions:
Product Height (in.): 1.25”
Product Width (in.): 2”
Product Depth (in.): 2”
Unit Weight: 0.15 lbs.