Categories
HVAC Equipment & Parts
- Air Handlers
- Air-To-Water Heat Pumps
- Condensate Overflow Shut-off Switches
- Condensate Removal & Management
- Condenser Pads
- Condensers (Outdoor Units)
- E-Z Traps
- Electric Heat Kits
- Furnaces
- Gas Furnace and A/C Systems
- Gas-Fired Unit Heaters
- Geothermal Units
- Goodman Replacement Parts
- Heat Pumps
- Indoor Units
- Install & Duct Tape
- Installation Accessories
- Linesets
- Miscellaneous Supplies
- Mounting Brackets
- Mr. Cool Universal Series
- Packaged Units
- Portable AC and Heat Units
- Refrigerant Coils
- Secondary Drain Pans
- Service Parts
- Sheet Metal Duct & Fittings
- Surge Protection
- Thermostats and Thermostat Wire
- Through The Wall Units
- Window Units
- More categories
Mini-Splits & Accessories
- Concealed Indoor Units
- Ducted Air Handler
- Ducted Mini-Split Air Handler
- Ductless Accessories
- Electric Heater Module
- Indoor Ceiling Cassettes
- Indoor Wall Mounted
- Intelli-HEAT Coil
- Mini Split Wire & Cable
- Mini-Split Risers
- Mitsubishi Mini-Splits
- Mr. Cool Ductless Mini-Splits
- Outdoor Units, Multi-Zone
- Outdoor Units, Single-Zone
- ProFit Quick Connect Fittings
- More categories
ICM Controls ECA500-11-208000 Motor Protection Relay 208/220VAC CT External
ICM Controls ECA500-11-208000 Motor Protection Relay 208/220VAC CT External
General specs
- Product codeECA500-11-208000
- ManufacturerICM Controls
- SKUECA500-11-208000
Dimensions
- Dimensions0.00in x 0.00in x 0.00in
- Weight0.00lb
ICM Controls ECA500-11-208000 Motor Protection Relay 208/220VAC CT External
Description:
The ECA500-11 is a series of micro-controlled 3-phase total motor protection current, voltage & power monitoring relays.
They’re designed to protect electrical loads and motors from failure and damage due to common current and voltage faults.
The ECA500-11’s constantly supervise current and voltage values and when any harmful condition occurs, the output connection is deactivated until the fault disappears, power line conditions return to acceptable levels and the motor has cooled to an acceptable temperature level.
Specific timing features such as Start Up Delay (TC) and Trip Delay (TD) are incorporated to prevent nuisance tripping due to rapid power fluctuations.
General Features:
Measuring of Current, Voltage, Frequency, Temperature, PF, KVA, KWH and KW
Fully adjustable protection parameters
LCD Display with 4 button operation
Reports: Load, Voltage, Current, Frequency, PF, KVA, KWH & KW, Values, Run Time, Temperature, Start Mode, Last 20 Faults and more
Din rail, Flat surface, or Flush mounting
Comm Port (MODBUS RTU protocol on RS485@9600 baud output)
Meets IEEE, IEC & NEMA standards, UL Listed
Specifications:
Brand | ICM Controls |
Product Type | Voltage Monitor |
Power Phase | 3 Phase |