Live chat
Support1-215-316-5893(Guest ID: 10728399)

Coleman ZE048H12A2A1ABA1A3 4 Ton Single Packaged Air Conditioners

$6,948.65
Category:Packaged Units
Manufacturer:Coleman
SKU:ZE048H12A2A1ABA1A3
Product code:ZE048H12A2A1ABA1A3
Product available
Coleman ZE048H12A2A1ABA1A3 4 Ton Single Packaged Air Conditioners
$6,948.65

General specs

  • Product codeZE048H12A2A1ABA1A3
  • ManufacturerColeman
  • SKUZE048H12A2A1ABA1A3

Dimensions

  • Dimensions83.00in x 45.00in x 33.00in
  • Weight668.00lb

Technical Specifications

  • Brand Coleman
  • Capacity 49,100 BTU
  • Compressor Type Scroll
  • EER2 11.2
  • Frequency 60Hz
  • Nominal CFM 1450
  • Nominal Tons 4 Ton
  • Phase 3
  • Refrigerant R-410A
  • SEER2 13.4
  • Sound Level 79 dBA
  • Voltage 208-230 V
  • Brochure
  • Installation Instruction
  • Service Manual
  • Submittal Sheet
  • Technical Manual

Coleman ZE048H12A2A1ABA1A3 4 Ton Single Packaged Air Conditioners

Description:

  • Convertible Single Package Rooftops: ZE/XN Series units designed with a common roof curb for 3, 4, 5, and 6 ton sizes.
  • Mounting Options: Primarily for curb mounting on roofs; can also be slab-mounted at ground level or set on steel beams above finished roofs.
  • Self-Contained Units: Assembled on rigid full perimeter base rails allowing for overhead rigging.
  • Factory Preparation: Each unit is completely charged, wired, piped, and tested at the factory for quick field installation.
  • Duct Connection Flexibility: All models, including those with an economizer, are convertible between bottom and horizontal duct connections.
  • ZE Series Configurations:
  • Cooling only
  • Cooling with single-stage gas heat
  • Electric heaters available as a field-installed accessory

Features:

  • Factory-assembled Units: Available configurations include Electric Cooling/Gas Heat, Electric Cooling, and Heat Pump.
  • Outdoor Installation: Designed specifically for outdoor mounted installation.
  • Efficiency Ratings:
  • 3, 4, and 5 ton units: Minimum SEER rating of 14.0.
  • Heat pumps: Minimum H.S.P.F. of 8.0.
  • 6 ton units: Minimum IEER rating of 14.2.
  • Convertible Duct Connections: Built-in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return.
  • Installation Options: Available with factory-installed options or field-installed accessories.
  • Factory Testing: Units are factory wired, piped, charged with R-410A refrigerant, and tested prior to shipment.
  • Wiring Standards: All unit wiring is numbered and color-coded for easy identification.
  • Compliance Standards: Cooling performance rated according to DOE and AHRI test procedures.