-
Categories
HVAC Equipment & Parts
- Air Handlers
- Air-To-Water Heat Pumps
- Condensate Overflow Shut-off Switches
- Condensate Removal & Management
- Condenser Pads
- Condensers (Outdoor Units)
- E-Z Traps
- Electric Heat Kits
- Furnaces
- Gas Furnace and A/C Systems
- Gas-Fired Unit Heaters
- Geothermal Units
- Goodman Replacement Parts
- Heat Pumps
- Indoor Units
- Install & Duct Tape
- Installation Accessories
- Linesets
- Miscellaneous Supplies
- Mounting Brackets
- Mr. Cool Universal Series
- Packaged Units
- Portable AC and Heat Units
- Refrigerant Coils
- Secondary Drain Pans
- Service Parts
- Sheet Metal Duct & Fittings
- Surge Protection
- Thermostats and Thermostat Wire
- Through The Wall Units
- Window Units
- More categories
Mini-Splits & Accessories
- Concealed Indoor Units
- Ducted Air Handler
- Ducted Mini-Split Air Handler
- Ductless Accessories
- Electric Heater Module
- Indoor Ceiling Cassettes
- Indoor Wall Mounted
- Intelli-HEAT Coil
- Mini Split Wire & Cable
- Mini-Split Risers
- Mitsubishi Mini-Splits
- Mr. Cool Ductless Mini-Splits
- Outdoor Units, Multi-Zone
- Outdoor Units, Single-Zone
- ProFit Quick Connect Fittings
- More categories
Paragon 8145-00 Defrost Timer 120V
Paragon 8145-00 Defrost Timer 120V
General specs
- Product code8145-00
- ManufacturerParagon
- SKU8145-00
Dimensions
- Dimensions0.00in x 0.00in x 0.00in
- Weight0.00lb
Paragon 8145-00 Defrost Timer 120V
Description:
The Paragon® 8000 Series Commercial Defrost Controls are designed for commercial freezers and refrigerators to provide automatic defrost capability.
They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle.
General Features:
Time initiated; temperature, pressure or time terminated models available
High-amp switch contacts: 40 Amps, 2 HP
Positive slider bar switch design assures positive electrical contact and wipes the contact surface of contaminates
Temperature or pressure terminated models are designed for defrost termination using an external temperature or pressure device
Safety back-up - mechanical time-driven defrost termination
Heavy-duty synchronous design drive motor
Choice of three contact arrangements
Adjustable frequency of defrost initiation from 1 to 6 cycles per day with a minimum of 4 hours between successive operations
Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments
Heavy-duty steel enclosure with knockouts (on the bottom, back and sides) and hasp and staple padlock
All 8240 models have an adjustable cut-in pressure dial calibrated from 36-110 pounds for R12, R22, R502
Specifications:
Series Application | Electric Heat, Hot Gas or Compressor Shutdown |
Electrical Rating | 120V AC, 60 Hz; 120V AC, 50 Hz |
Switch Rating | 40 Amps, 2HP, 690 VA, 120-240V AC |
Initiation/Termination Type | Time / Temperature or Pressure |
Enclosure | Heavy Duty Steel |
Switch Arrangement for Contacts 1-3 | Open |
Switch Arrangement for Contacts 2-4 | Closed |
Switch Arrangements for Contacts 3-N | None |
Agency Approvals | UL Listed | UL Recognized |