Live chat
Support1-215-316-5893(Guest ID: 1247486)

ICM Controls ICM6700 12 VDC Direct Spark Ignition Control Board

$93.62
Category:ICM Controls
Manufacturer:ICM Controls
SKU:ICM6700
Product code:ICM6700
Product available

Shipping options

Shipping to United States, Pennsylvania, Norristown, 19401
Flat Rate
Ground shipping. Most items ship SAME DAY.
$9.99
FREE - Pickup From Store
Pick up your purchase and eat pizza with us at one of our Warehouses
$0.00
RUSH - 2 Day
Your order will ship 2 day air. Please allow 1 business day for processing.
$29.95
RUSH - Next Day
Next Day Air Shipping. Please allow 1 business day for processing.
$75.95
*Shipping quotes are calculated for 1 pc of this particular product.
ICM Controls ICM6700 12 VDC Direct Spark Ignition Control Board
$93.62

General specs

  • Product codeICM6700
  • ManufacturerICM Controls
  • SKUICM6700

Dimensions

  • Dimensions0.00in x 0.00in x 0.00in
  • Weight0.00lb
  • Installation manual
  • Specification Sheet

ICM Controls ICM6700 12 VDC Direct Spark Ignition Control Board


Description:


  • Suburban Replacement. This ignition control circuit board works on all Suburban 12V furnaces and Suburban water heater model 520820.

  • When the thermostat calls for heat, the ICM6700 will verify the sail switch is open before energizing the inducer blower. 

  • Once the inducer blower is energized, the ICM6700 will verify the sail switch has closed and begin a 15 second pre-purge cycle. 

  • Following the inducer blower pre- purge cycle, the gas valve and spark ignitor are energized and the ICM6700 will verify the presence of flame.

  • If flame has not been sensed after 7 seconds; the control will attempt 2 more trials for ignition, if flame is not sensed after 3 trials for ignition, the ICM6700 will enter a 1-hour lockout. 

  • If flame is detected, the spark ignitor is turned off and the gas valve remains energized. Once the thermostat is satisfied, the gas valve is de-energized immediately and a 90 second post-purge cycle of the inducer blower is enforced. 

  • After the 90 second post purge cycle, the inducer blower is turned off. 


  • Note: Lockout is cleared by recycling the input voltage.


General Features:


  • Direct Spark Ignition (DSI) control board

  • Monitors timing, Trial for ignition, flame sensing and lockout

  • Designed for 100% gas shutoff in the case of ignition failure

  • Microprocessor-based precision

  • Designed for 100% gas shutoff in the case of ignition failure


Specifications:


Input

Voltage

12 VDC

Current Draw

100mA max.

Output

Gas Valve: N.O.

0.5A @ 12 VDC

Inducer Blower

3.7A @ 12 VDC

Time Delay

Trial for Ignition

7 seconds

ON Delay

15 seconds

OFF Delay

90 seconds


Replaces: 


Fenwal

06-236879-002

Suburban

521099

35-533900-113



Top