Categories
HVAC Equipment & Parts
- Air Handlers
- Air-To-Water Heat Pumps
- Condensate Overflow Shut-off Switches
- Condensate Removal & Management
- Condenser Pads
- Condensers (Outdoor Units)
- E-Z Traps
- Electric Heat Kits
- Furnaces
- Gas Furnace and A/C Systems
- Gas-Fired Unit Heaters
- Geothermal Units
- Goodman Replacement Parts
- Heat Pumps
- Indoor Units
- Install & Duct Tape
- Installation Accessories
- Linesets
- Miscellaneous Supplies
- Mounting Brackets
- Mr. Cool Universal Series
- Packaged Units
- Portable AC and Heat Units
- Refrigerant Coils
- Secondary Drain Pans
- Service Parts
- Sheet Metal Duct & Fittings
- Surge Protection
- Thermostats and Thermostat Wire
- Through The Wall Units
- Window Units
- More categories
Mini-Splits & Accessories
- Concealed Indoor Units
- Ducted Air Handler
- Ducted Mini-Split Air Handler
- Ductless Accessories
- Electric Heater Module
- Indoor Ceiling Cassettes
- Indoor Wall Mounted
- Intelli-HEAT Coil
- Mini Split Wire & Cable
- Mini-Split Risers
- Mr. Cool Ductless Mini-Splits
- Outdoor Units, Multi-Zone
- Outdoor Units, Single-Zone
- More categories
ICM Controls ICM2910-205-521 Direct Spark Ignition Control, 120v w/ 5 sec. Prepurge (4 sec TFI)
ICM Controls ICM2910-205-521 Direct Spark Ignition Control, 120v w/ 5 sec. Prepurge (4 sec TFI)
General specs
- Product codeICM2910-205-521
- ManufacturerICM Controls
- SKUICM2910-205-521
Dimensions
- Dimensions5.23in x 2.53in x 1.86in
- Weight1.00lb
ICM Controls ICM2910-205-521 Direct Spark Ignition Control, 120v w/ 5 sec. Prepurge (4 sec TFI)
Description:
The ICM2910 consists of a series of 11 Fenwal OEM Replacement DSI Controls.
When the thermostat initiates a "Call for Heat", the ICM2910 will perform a hardware check.
After the hardware check, the ICM2910 will start a pre-purge where applicable.
Once the pre-purge has ended, the spark source and the gas valve relay are energized simultaneously for the duration of the trial for ignition period.
A flame rectification circuit confirms the presence of the flame.
Upon flame detection, the spark source is turned off.
If flame is not sensed, the control will turn off the spark source and gas valve and start an inter-purge where applicable before the next trial for ignition.
If flame is not detected after the trial(s) for ignition, the control will enter a hard lockout.
To clear the hard lockout, remove the input voltage to the control or recycle the thermostat’s heat call.
General Features:
Direct Spark Ignition (DSI) control modules
Microprocessor-based
Controls spark ignitor and gas valve
Monitors timing, trial for ignition, flame sensing and lockout
Compatible with LP or natural gas
Redundant Gas valve design conforms to ANSI Z21.20
Conforms to UL STDs 60730-1 and 60730-2-5.
Certified to CSA STD E60730-1 and CSA STD C22.2#60730-2-5
Specifications:
Control Voltage | 102-138 VAC |
Flame Current | 1uA minimum |
Current Draw | 50mA maximum |
Gas Valve | 1.5A, 120 VAC |
Flame Failure Response Time | 0.8 seconds maximum |
Operating temperature | -40°F to 175°F (-40°C to 80°C) |
Mounting | Surface mount using (2) No.8 screws |
Replaces:
Fenwal | 35-725205-521 |
Dimensions:
Product Height (in.): 1.86”
Product Width (in.): 2.53”
Product Depth (in.): 5.23”